Disinfection Room Mobides / Mobidis

Description
Removes 99.9% of bacteria, viruses, fungi and other germs.

MobiDES is a liquid biocidal disinfectant with excellent disinfection behavior.Pathogenic germs are reliably inactivated by the oxidative, oxygen-releasing effect. It disinfects all water-resistant surface sandi nventory in public buildings,office buildings, airports,kitchens, sanitary, household and other areas. Effective against micro organisms and biofilms.

MobiDES can also be used to disinfect room atmosphere by fin enebulization.

MobiDES is free of alcohols, ammonium compounds or solvents and does not contain copper or silver ions. The pH is in the neutral range of 7 – 8.5 which is gentle on skin.

Product advantages

  • Short exposure time, broad antimicrobial spectrum of action
  • Depot effect inhibits new germination
  • Sustainable effectiveness: No formation of resistances possible
  • Ingredients effective against: SARS-CoV-2, P.aeruginosa, E.coli, L.pneumophilau.a.
  • Free of allergens and fragrances

PROPERTIES
  • Active Ingredients : Solution of approx. 0.03% chlorine dioxide generated
  • Dosage form : Ready-to-use solution for spray or wipe application
  • Concentration of active substance : < 300 ppm

Synergetic combination of disinfecting chlorine-oxygen ­compounds

Effective against 99.9% of pathogenic germs, such as Bacteria, Viruses, Fungi and others

Ensures reliable surface disinfection, suppresses new germ formation

APPLICATION

Objects and surfaces are sprayed from a distance of approx. 30 cm until fully wetted. Alternatively wipe disinfection is possible. Leave on surface for 60 seconds and wipe with a cloth. Alternatively rinse with water. In the case of sensitive surfaces, make a resistance test at an inconspicuous place if necessary.

All information is only a guideline. The actual dosage depends on degree of contamination. Frequency of use as required.

SAFETY INSTRUCTIONS

Use biocidal products carefully. Always read the label and product information before use. Keep out of reach for children.

Do not put solution in eye or onto mucous membranes. Based on the available data, the product is not a hazardous mixture according to European guidelines or Dangerous Goods guidelines.

The product can be stored in tightly closed container under cool and dark conditions for 18 months without loss in efficacy. Keep out of reach for children and away from food, drink and animal feed. Store away from acids

Complies with EU Biocidal Products Regulation (EU) 528/2012, Art. 95 (2).

Ingredients: Composition of chlorine-oxygen-compounds.


TYPES OF PACKAGING
  • 250 / 500 mL spray bottle
  • 5 / 10 / 25 L canister
  • 200 L drum
  • 1000 L IBC
Description
Disinfection container Mobides/Mobidis
  • Whole body disinfection through nebulization system
  • Room system with two integrated hygienic locks
  • Pump unit
  • Spray glands for optimal distribution
  • Complete solution, ready for immediate use
Dimensions
  • Approx. 6.00 x 2.40 m (wxd), optional 3.00 x 2.40 m (wxd)
Technical requirement
  • Power connection 230v, flat underground

Whole body disinfection through spray mist

Where many sick and germ-laden people are gathered together in one area, it is important to contain infections and diseases. The disinfection is a hygienic measure, which helps to kill or inactivate viruses, pathogens, bacteria and germs. Through the current Corona Pandemic, the whole-body disinfection is not only indispensable in medical practices and clinics. The mobile disinfection container can be placed al- most everywhere in a short amount of time.

The disinfectant is sprayed from nebulizing glands

The fine spray is optimally distributed over the complete surface are of the body

Optional: Examination lock
An examination lock for samples can get integ- rated

Layout And Function

The scope of delivery includes a pump unit including a filter. The pump unit is connected to a water supply and distributes it to the downstream sys- tems with appropriate pressure. The pump unit can be preceded by other systems such as a dosing unit or water treatment systems.

The pump unit has three adjustable operating modes

1. manual mode   2. automatic mode   3. rinse mode


Description
  1. tubular frame
  2. control unit
  3. rubber puffer
  4. manometer low pressure, high pressure
  5. thermal valve 50 °C
  6. filter unit
  7. high pressure hose HD110 – 1000 mm 12 l with connection (different lengths on request)
  8. pressure valve

Optics may vary, depending on availability. Function identical.

The pump unit is generally equipped with a pres- sure regulator, pressure monitor, pressure gauge and pump holder.

Optics may vary, depending on availability. Function identical.

Output

1 ltr/min – 7 ltr/min


Number of glands max (5l/h)

12 – 96


Max. building size

700 m2


Max. operating pressure

50 bar


Engine power

2,2 kW


Current consumption

9,2 A


Tension

230v


Weight

49 kg


Dimension in mm

710 x 450 x 450


Required oil quantity

0,35 l


Possibility 1: Mobile room with to disinfection areas for each 4 persons:

The room system has two integrated disinfection areas for each 4 persons. There is space for 8 persons to get a whole-body disinfection at the same time, but disinfection takes place inde- pendently from each other in the two areas. The “black area” is the not disinfected part. The persons will meet in this area first. After they will go through the hygienic gate to the disinfection area. This is where the disinfection takes place. Finally, disinfected persons leave the room via the exit in the white area.

Possibility 2: contactless examination

  • Separation of disinfection area and examination lock (saliva or similar samples can be taken through a glass partition with a gloves system) – contactless

Procedure

  • Entrance through the “black area”
  • Right disinfection area – to take samples with the glo- ves system
  • Left disinfection area – whole-body disinfection in 30 to 40 seconds (max. 4 persons)
  • Exit through the “white area” on the left


Possibility 3:

  • One disinfection area of 30 to 40 seconds (max. 4 persons)
  • Procedure like possibility 1


Possibility 4:

  • Disinfection gate – continuous disinfection
  • Time to go through – 30 to 40 seconds while the per- son is going slowly through the gate

  • Whole-body disinfection in less than 60 seconds
  • Persons meet in front of the entrance, enter the disinfection container (safety googles)
  • Start of the system by pressing the button
    (red signal will appear at the traffic light system)
  • Entering the disinfection area in 10 seconds
    Position / note food position (floor marking)
  • Disinfection through spray mist starts
    < than 60 seconds including aftermath
  • Traffic light system changes to green
  • Exit the disinfection area
    Enter the white area (disinfected)